Taking the complementary power generation system of a 660 MW coal-fired unit assisted by solar thermal energy as the research object
a dynamic simulation model was established for the solar hybrid coal power generation system. Based on this
the impacts of the molten salt storage and solar energy integration on the dynamic response of the solar hybrid coal power generation system were discussed through 6 typical operational schemes. The results show that: under safe operating conditions
comparing the three load reduction schemes
the peaking capacity and load changing rate of solar hybrid coal power generations system are the largest under the operation condition of main steam being extracted and exhaust steam entering the condenser
which can reach 56.5 MW and 6.7%/min respectively; comparing the two system load increase schemes
the molten salt heating feedwater bypass scheme demonstrates superior peaking capacity (up to 32.4 MW)
while the molten salt heating condensate bypass scheme exhibits a higher load changing rate (up to 8.45%/min). Comparing the change of standard coal consumption rate under three different solar heat introduction complementary system schemes
the use of molten salt heating boiler feedwater coal saving effect is the best
the standard coal consumption rate can be reduced by 25.47 g/kWh at most
and the higher generated power of solar hybrid coal power generation system
the greater the coal saving rate.
关键词
Keywords
references
WU J J, HAN Y, HOU H J.A new solar share evaluation method of solar aided power generation (SAPG) system by tracing exergy flows and allocating exergy destruction[J]. Solar energy, 2020, 198: 542-554.
ZHANG N, HOU H J, YU G, et al.Simulated performance analysis of a solar aided power generation plant in fuel saving operation mode[J]. Energy, 2019, 166: 918-928.
PATNODE, ANGELA M.Simulation and performance evaluation of parabolic trough solar power plants[D]. Madison, Wisconsin:University of Wisconsin-Madison, 2006.