1. 同济大学 土木工程防灾国家重点实验室,上海,200092
2. 同济大学 桥梁结构抗风技术交通运输行业重点实验室,上海,200092
3. 中南安全环境技术研究院股份有限公司,武汉,430070
4. 中国电力工程顾问集团 东北电力设计院有限公司,长春,130021
赵林(1974-),教授,博导,主要从事桥梁与结构风工程研究. E-mail:zhaolin@tongji.edu.cn
陈翰林*(1994-),硕士,从事桥梁与结构风工程研究. E-mail:2545960181@qq.com
纸质出版:2021
移动端阅览
赵林, 陈翰林, 钱永丰, 等. 冷却塔群塔干扰条件下脉动风压分布模式[J]. 空气动力学学报, 2021, 39(3): 33−43.
ZHAO Lin, CHEN Hanlin, QIAN Yongfeng, et al. Distribution patterns of fluctuating wind pressure of grouped cooling towers[J]. 2021, 39(3): 33-43.
赵林, 陈翰林, 钱永丰, 等. 冷却塔群塔干扰条件下脉动风压分布模式[J]. 空气动力学学报, 2021, 39(3): 33−43. DOI: 10.7638/kqdlxxb-2020.0180
ZHAO Lin, CHEN Hanlin, QIAN Yongfeng, et al. Distribution patterns of fluctuating wind pressure of grouped cooling towers[J]. 2021, 39(3): 33-43. DOI: 10.7638/kqdlxxb-2020.0180.
冷却塔群塔为常见的群体建筑物组合形式,存在复杂的塔群干扰效应。传统的群塔干扰效应研究通常面向塔筒等效静风荷载,忽略了群塔组合对于脉动风压分布模式干扰效应的量化研究。为了研究群塔组合条件下脉动风压的干扰分布模式,选取具备多种气动干扰特点的八塔组合矩形布置方案为研究对象,对群塔进行刚性模型同步测压风洞试验,获取了不同风向角条件下塔筒表面的脉动风压分布。在“迎风来流”、“侧风来流”和“背风来流”等三种典型来流模式下,结合风向角的变化将脉动风压分布形式总结为“V”型、“M”型、半“V”型+半“M”型三类,探讨了干扰影响脉动风压分布的机理,发现可将脉动荷载的干扰效应分为“弱干扰”、“非对称强干扰”和“对称强干扰”三种类别;在量化表达脉动风压干扰分布方面提出了脉动风压分布的九项式拟合公式,并按照三类分布模式给出了脉动风压的推荐表达式。
As a typical building combination form
the grouped cooling towers can have a complicated grouped-tower interference effect. Traditional studies on the grouped-tower interference effect usually emphasized the equivalent static wind load of the tower tubes
while ignored the quantitative analysis on the fluctuating wind pressure distribution patterns. In order to quantify the distribution patterns of the fluctuating wind pressure under the condition of grouped-tower combination
a rectangular arrangement of eight towers with various aerodynamic interference characteristics was selected as the research object. A rigid model synchronizing pressure measurement for the grouped cooling towers was used in the wind tunnel test
and the fluctuating wind pressure on the tower surface at different wind direction angles was obtained. Based on three typical inflow modes
i.e.
"windward flow"
"crosswind flow" and "leeward flow"
the fluctuating wind pressure distribution can be categorized into a "V" type
a "M" type
and a half "V" + half "M" type. The interference mechanism for the fluctuating pressure distribution was explored
and it is found that the interference effect from the fluctuating wind load can be summarized as three types: "weak interference"
"asymmetric strong interference" and "symmetric strong interference". A 9-term fitting formula for the fluctuating wind pressure was proposed
and recommended expressions were given according for the three distribution patterns of the fluctuating wind pressure.
Q/DG 1-SO12-2011. 超大型冷却塔塔设计导则[S]. 中国电力工程顾问集团, 2011.
NIEMANN H J, KÖPPER H. Influence of adjacent buildings on wind effects on cooling towers[J]. Engineering Structures, 1998, 20(10): 874-880. doi: 10.1016/S0141-0296(97)00131-4.
NIEMANN H J, PRÖPPER H. Some properties of fluctuating wind pressures on a full-scale cooling tower[J]. Journal of Wind Engineering and Industrial Aerodynamics, 1975, 1: 349-359. doi: 10.1016/0167-6105(75)90029-X.
FLAGA A. Quasi-static computational approach to wind load on cooling towers in conditions of aerodynamic interference[J]. Engineering Structures, 1991, 13(4): 317-328. doi: 10.1016/0141-0296(91)90018-8.
ORLANDO M. Wind-induced interference effects on two adjacent cooling towers[J]. Engineering Structures, 2001, 23(8): 979-992. doi: 10.1016/S0141-0296(00)00110-3.
GU Z F, SUN T F. Experimental research on flow around three circular cylinders[J]. Acta Aerodynamica Sinica, 2000, 18(4): 441-447. (in Chinese).
GU Z F, SUN T F, LIN R S. Time-mean pressure on the surface of two circular cylinders in tandem arrangements at high Reynolds numbers[J]. Acta Aerodynamica Sinica, 1997, 15(3): 393-399. (in Chinese).
GU Z F, SUN T F, HE D X, et al. Pressure fluctuations on the surface of two circular cylinders in tandem arrangements at high Reynolds numbers[J]. Acta Aerodynamica Sinica, 1992, 10(2): 176-184. (in Chinese)[知网].
ZHAO L, GE Y J, XU L S, et al. Wind tunnel investigation on wind-induced interference effects for supre large cooling towers[J]. Engineering Mechanics, 2009, 26(1): 149-154, 159. (in Chinese).
ZHAO L, ZHAN Y Y, CHEN X, et al. Wind-induced interference criterion for grouped cooling towers based on the index of reinforcement ratio envelope[J]. Engineering Mechanics, 2018, 35(5): 65-74. (in Chinese).
YU M, ZHAO L, ZHAN Y Y, et al. Wind-resistant design and safety evaluation of cooling towers by reinforcement area criterion[J]. Engineering Structures, 2019, 193(3): 281-294. doi: 10.1016/j.engstruct.2019.05.031.
ZHAO L, LI P F, GE Y J. Numerical investigation on performance of super large cooling towers under equivalent static wind load[J]. Engineering Mechanics, 2008, 25(7): 79-86. (in Chinese)[知网].
KE S T, WANG H, YU W. Interference effect of wind loads for super large cooling tower under typical four towers combinations[J]. Journal of Tongji University (Natural Science), 2017, 45(10): 1421-1428. (in Chinese).
KE S T, YU W L, WANG H, et al. Research on interference effect of super large cooling towers with two tower combinations under complex mountains[J]. Journal of Experiments in Fluid Mechanics, 2018, 32(4): 61-71. (in Chinese).
SHEN G H, YU G P, SUN B N, et al. Study on interference effects of two large hyperbolic cooling towers by using wind tunnel test[J]. Journal of Vibration and Shock, 2011, 30(3): 109-114. (in Chinese)doi: 10.13465/j.cnki.jvs.2011.03.053.
SHEN G H, YU G P, SUN B N, et al. Study of wind-induced interference effects on three adjacent cooling towers under upside-down triangular distribution[J]. Acta Aerodynamica Sinica, 2011, 29(1): 107-113. (in Chinese).
ZHANG J F, ZHAO L, KE S T, et al. Wind tunnel investigation on wind-pressure interference effects for two large hyperboloidal cooling towers[J]. Journal of Harbin Institute of Technology, 2011, 43(4): 81-87. (in Chinese).
ZHANG J F, GE Y J, ZHAO L. Interference effects on global wind loads and wind induced responses for group hyperboloidal cooling towers[J]. Engineering Mechanics, 2016, 33(8): 15-23, 44. (in Chinese).
ZHANG J F, GE Y J, ZHAO L, et al. Wind tunnel study on the three dimensional flow and spatial correlation properties of wind loads on hyperboloidal cooling towers[J]. Engineering Mechanics, 2013, 30(9): 234-242. (in Chinese).
ZHAO L, WANG Z N, LIANG Y W, et al. Structural optimization considering various wind load distribution patterns of large cooling towers[J]. Acta Aerodynamica Sinica, 2018, 36(3): 493-504. (in Chinese).
ZHAO L, CUI W, ZHAN Y Y, et al. Optimal structural design searching algorithm for cooling towers based on typical adverse wind load patterns[J]. Thin-Walled Structures, 2020, 151: 106740. doi: 10.1016/j.tws.2020.106740.
ZHOU L M, LI P H. Measurement of wind pressure distribution in two adjacent full-scale hyperbolic cooling towers[J]. Pneumatic Experiment and Measurement Control, 1992, 6(3): 37-44. (in Chinese).
PIRNER M. Wind pressure fluctuations on a cooling tower[J]. Journal of Wind Engineering and Industrial Aerodynamics, 1982, 10(3): 343-360.
Gu Z F, Sun T F, JI S D. Wind tunnel study on wind load of cooling towers in Shalingzi power plant[J]. Acta mechanica Sinica, 1992, 24(2): 129-135. (in Chinese) OI: 10.1016/0167-6105(82)90006-X.
SUN T F, GU Z F. Interference between wind loading on group of structures[J]. Journal of Wind Engineering and Industrial Aerodynamics, 1995, 54-55: 213-225. doi: 10.1016/0167-6105(94)00051-E.
SUN T F, GU Z F, HE D X, et al. Fluctuating pressure on two circular cylinders at high Reynolds numbers[J]. Journal of Wind Engineering and Industrial Aerodynamics, 1992, 41(1-3): 577-588. doi: 10.1016/0167-6105(92)90467-O.
BAO K Y, SHEN G H, SUN B N. Numerical simulation of fluctuating wind load and wind-induced response of large hyperbolic cooling tower[J]. Journal of Zhejiang University (Engineering Science), 2010, 44(5): 955-961. (in Chinese).
BABU G R, RAJAN S S, HARIKRISHNA P, et al. Experimental determination of wind-induced response on a model of natural draught cooling tower[J]. Experimental Techniques, 2013, 37(1): 35-46.DOI: 10.1111/j.1747-1567.2011.00715.x.
KE S T, WANG H, GE Y J. Non-Gaussian characteristics and extreme distribution of fluctuating wind pressures on large cylindrical-conical steel cooling towers[J]. The Structural Design of Tall and Special Buildings, 2017, 26(18): e1403. doi: 10.1002/tal.1403.
ZHAO L, LIU X P, GAO L, et al. Full-scale measurement and distribution rules of surface fluctuating wind pressure of a large cooling tower[J]. China Civil Engineering Journal, 2017, 50(1): 1-11. (in Chinese)doi: 10.15951/j.tmgcxb.2017.01.001.
ZHAO L, GE Y J, KAREEM A. Fluctuating wind pressure distribution around full-scale cooling towers[J]. Journal of Wind Engineering and Industrial Aerodynamics, 2017, 165: 34-45. doi: 10.1016/j.jweia.2017.02.016.
ZHAN Y Y, ZHAO L, LIANG Y W, et al. Comprehensive assessment of wind-induced interference criteria about large cooling towers with typical six-towers double-columns arrangements[J]. Engineering Mechanics, 2017, 34(11): 66-76. (in Chinese).
CHENG X X, ZHAO L, GE Y J. Wind tunnel investigation on interference effect of eight grouped super large cooling towers with rectangular arrangement[J]. Journal of Central South University (Science and Technology), 2013, 44(1): 372-380. (in Chinese).
Ministry of Housing and Urban Rural Development of the People's Republic of China. Recommended national standards of the People's Republic of China: Code for design of industrial circulating water cooling tower. GB/T 50102—2014[S]. China Planning Press, Beijing, 2015. (in Chinese).
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621