HUANG Rui, ZHANG Shengyan, SHI Haonan, et al. Active damping control method of cascade system for lossy LC filter and Buck converter[J]. Ningxia Electric Power, 2024, (4).
HUANG Rui, ZHANG Shengyan, SHI Haonan, et al. Active damping control method of cascade system for lossy LC filter and Buck converter[J]. Ningxia Electric Power, 2024, (4).DOI: 10.3969/j.issn.1672-3643.2024.04.009.
In a cascaded system consisting of LC filters and Buck converters with constant loads
improper design of the front-end circuit's LC filter parameters can lead to voltage oscillations due to parameter mismatches between stages.Although existing research has explored approximate linearization modeling
impedance ratio criteria
and damping control design of the system
they have overlooked the impact of filter losses.So this paper proposes a system circuit model that includes filter loss parameters.Based on this model
small-signal equations are formulated to derive the equivalent impedance of the system port.Subsequently
the Routh-Hurwitz Criterion is applied to analyze the influence of loss parameters on system stability
leading to the design of individual transfer functions for the system's active damping feedforward control loop.Finally
the effectiveness of this control method is evaluated and validated through impedance ratio criterion