Tang Lu-xin, Li Jie, Luo Xi-hai, et al. Design of a Strong Magnetic Field Measurement Based on Error and Interference Optimization[J]. 2012, 29(4): 27-32.
Tang Lu-xin, Li Jie, Luo Xi-hai, et al. Design of a Strong Magnetic Field Measurement Based on Error and Interference Optimization[J]. 2012, 29(4): 27-32.DOI: 10.3969/j.issn.1007-7162.2012.04.006.
By analysing the operating condition of space point measurement of IF strong magnetic field and computing the error of signal processing circuits
it finds out the major factors leading to errors. In order to improve the accuracy of the measuring instrument
real time property and anti-interference ability
an optimization method of combining hardware and software is presented. In the signal regulating circuit
the errors were significantly reduced by reasonably configuring the amplification factors of pre and post stage
relative resistor and using high-precision operational amplifier. Interference was suppressed effectively by employing two hardware and uniquely mean filtering methods. Via the use of the least square method to optimize data fitting parameters
errors caused by rectifier
filter and programmable amplifier circuit were reduced further
which improved the whole performance. The experimental results obtained by testing the optimized measuring instrument
show that measurement error is less than ±1.5%
consistency error is less than 1%