Aiming at the problems of high bed temper-ature and large concentration of NOx emission in a 200MW circulating fluidized bed boiler
the boiler is studied in this paper:the experimental analysis is carried out re-spectively from adjustment of fluidizing air volume
running oxygen rate
ratio of up and down secondary air and bed pressure.The experimental results show that with the in-crease of fluidizing air
the bed temperature and NOx emis-sion increased significantly;With the increase of running oxy-gen
bed temperature decreased significantly
NOx emissions increased significantly;Properly reducing the bed pressure and closing the opening of the lower secondary air register can effectively reduce the bed temperature and inhibit the formation of NOx.Through a vari
ety of combustion adjust-ment means
the NOx emission concentration under three loads can be controlled below 240mg/m