1. 国源电力(神东电力)公司技术支持中心
2. 西安热工研究院有限公司
纸质出版:2026
移动端阅览
寇斐, 赵勇纲, 王虎, 等. 空气动力试验装置均流结构设计与试验验证[J]. 热力发电, 2026,(10).
寇斐, 赵勇纲, 王虎, et al. 空气动力试验装置均流结构设计与试验验证[J]. Thermal Power Generation, 2026, (10).
寇斐, 赵勇纲, 王虎, 等. 空气动力试验装置均流结构设计与试验验证[J]. 热力发电, 2026,(10). DOI: 10.19666/j.rlfd.202602047.
寇斐, 赵勇纲, 王虎, et al. 空气动力试验装置均流结构设计与试验验证[J]. Thermal Power Generation, 2026, (10). DOI: 10.19666/j.rlfd.202602047.
【目的】为在有限空间内构建1:1的空气动力试验装置,解决离心风机出口极不稳定流场的均流难题,实现锅炉燃烧系统多环空间、复杂结构、不稳定流场风量测量的目的。【方法】本文运用CFD方法对比分析了空腔结构、内含双层蜂窝器的均流结构及新型复合式均流结构3种模型的流动特性及均流效果。【结果】空腔结构仅依靠管道的流场扩张,无法有效改善流场不均匀性;双层蜂窝器结构虽通过多孔结构进行初步整流并导直气流,但对速度梯度及湍流脉动的抑制有限;本文提出的新型复合式均流结构,通过均流孔板的多级阻力调节与蜂窝整流器的稳流导流作用,在宽风速范围内实现了流场分布的高度均匀化,标准测量段速度为10、30、50 m/s时,测量截面的速度标准偏差S
v
分别为0.281%、0.909%和1.401%。试验结果与数值模拟对比表明,采用新型复合式均流结构,速度标准偏差S
v
的偏差值分别为3.45%、4.21%及7.28%,验证了其准确性及优越性。【结论】研究揭示了新型复合式均流结构的整流作用机制,为空气动力试验装置的均流结构设计与性能优化提供理论支撑与技术路径。
[Objective
]
In many fields such as aerospace and energy engineering
aerodynamic testing equipment is a fundamental platform for key technology development and product performance testing. The uniformity of the flow field plays a decisive role in the accuracy and reliability of the test results. To construct a 1:1 aerodynamic testing device within a limited space
this study addresses the challenge of flow uniformization in the highly unstable flow field at the centrifugal fan outlet
aiming to achieve accurate airflow measurement in multi-ring spaces
complex structures
and unstable flow fields of boiler combustion systems. [Methods
]
This paper uses CFD numerical simulation to systematically compare the internal flow characteristics
flow field uniformity
and resistance characteristics of three sche
mes: a cavity structure
a flow uniformity structure containing a double-layer honeycomb structure
and a novel composite flow uniformity structure. Simultaneously
a physical test platform is built
and the numerical calculation and experimental measurement results are compared and verified using the velocity standard deviation(S
v
) as the core evaluation index. [Results
]
The results show that the cavity structure
relying solely on pipe expansion for natural rectification
cannot eliminate vortices
backflow
and large velocity gradients at the fan outlet
and the flow field uniformity continuously deteriorates with increasing wind speed. The double-layer honeycomb structure can break up large-scale vortices and straighten the airflow
but its ability to suppress velocity gradients and attenuate turbulent fluctuations is limited
resulting in poor flow uniformity at low wind speeds. The novel composite flow uniformity structure proposed in this paper achieves uniform velocity redistribution through multi-stage resistance control of the double-layer perforated plate. Combined with the flow stabilization and guidance of the honeycomb structure and the dissipation of small-scale vortices
it achieves a high degree of flow field uniformity across a wide wind speed range. When the wind speeds at the standard measurement section are 10
30
and 50 m/s
the standard deviations of velocity S
v
at the measurement sections are 0.281%
0.909%
and 1.401%
respectively. Comparison of experimental and numerical simulation results shows that the deviations of the standard deviation S
v
of the velocity of the novel composite flow uniformity structure are 3.45%
4.21%
and 7.28%
respectively
and the structural resistance is within the allowable head range of the system
indicating its outstanding flow uniformity performance and engineering applicability. [Conclusion
]
This study reveals the working mechanism of the synergistic rectification of the double-layer flow equalization plate and the hone
ycomb device
and verifies the technical superiority of the novel composite flow equalization structure under conditions of limited space
wide wind speed range
and unstable incoming flow. It provides theoretical support and an engineering technical approach for the design and performance optimization of flow equalization structure in aerodynamic test devices.
0