1. 华北电力大学自动化系
2. 天津中材工程研究中心有限公司
纸质出版:2026
移动端阅览
赵征, 姜贵文, 唐新宇, 等. 基于改进NSGA-Ⅱ算法的单塔双循环脱硫系统运行策略优化[J]. 热力发电, 2026,(8).
赵征, 姜贵文, 唐新宇, et al. 基于改进NSGA-Ⅱ算法的单塔双循环脱硫系统运行策略优化[J]. Thermal Power Generation, 2026, (8).
赵征, 姜贵文, 唐新宇, 等. 基于改进NSGA-Ⅱ算法的单塔双循环脱硫系统运行策略优化[J]. 热力发电, 2026,(8). DOI: 10.19666/j.rlfd.202601055.
赵征, 姜贵文, 唐新宇, et al. 基于改进NSGA-Ⅱ算法的单塔双循环脱硫系统运行策略优化[J]. Thermal Power Generation, 2026, (8). DOI: 10.19666/j.rlfd.202601055.
【目的】针对燃煤电厂单塔双循环湿法脱硫系统运行中出口SO
2
排放波动大及脱硫成本偏高的问题,提出一种基于预测模型与多目标优化算法相结合的混合优化策略,旨在实现系统环保达标与经济运行的双赢。【方法】首先,构建基于Transformer与双向长短时记忆网络(BiLSTM)相融合的预测模型,并创新性地采用改进黑翅鸢算法对该模型的关键超参数进行寻优,以克服经验调参的局限性并提升出口SO
2
质量浓度的预测精度;其次,建立综合考虑出口SO
2
质量浓度和系统脱硫成本的多目标优化模型,并采用改进NSGA-Ⅱ算法进行求解,得到可控变量的设定值。【结果】实验结果表明,改进黑翅鸢算法优化的Transformer-BiLSTM预测模型在均方根误差、平均绝对误差和平均绝对百分比误差指标上均优于BiLSTM、CNN-BiLSTM和Transformer-BiLSTM模型;同时,经改进NSGA-Ⅱ算法优化求解,系统得到了兼顾环保与经济的帕累托最优解。【结论】该混合优化策略有效降低了出口SO
2
质量浓度和脱硫成本,验证了所提方法在实现环保与经济运行方面的有效性。
[Objective
]
Driven by stringent environmental regulations
coal-fired power plants urgently require highly efficient and intelligent emission control technologies. The widely utilized single-tower dual-loop wet flue gas desulfurization(WFGD) system often faces significant challenges during practical operation
notably severe fluctuations in sulfur dioxide(SO
2
) emissions at the system outlet and high desulfurization costs. These issues primarily stem from the system's complex nonlinear dynamics
large inertia
and time-delay characteristics. To address these operational bottlenecks
this study proposes a novel hybrid optimization strategy integrating an advanced deep-learning prediction model with a multi-objective optimization algorithm. The primary g
oal is to achieve a win-win operational paradigm
ensuring strict environmental compliance while simultaneously minimizing economic expenditures. [Methods
]
The proposed strategy is implemented through a systematic twostage framework. First
a predictive model is constructed by fusing the Transformer architecture with a bidirectional long short-term memory(BiLSTM) network. The Transformer effectively captures global long-range dependencies of operational data
while the BiLSTM extracts complex bidirectional temporal features. To overcome the limitations of empirical hyperparameter tuning
an improved black-winged kite algorithm(BKA) is introduced. This heuristic algorithm systematically optimizes the model's key hyperparameters
significantly enhancing the forecasting accuracy of the outlet SO
2
concentration. Second
a comprehensive multi-objective optimization model is established
taking into account both the predicted outlet SO
2
concentration and the system's overall desulfurization costs as conflicting objectives. To solve this complex trade-off problem
an improved non-dominated sorting genetic algorithm II(NSGA-Ⅱ) is applied to optimize operational parameters and derive precise setpoints for key controllable variables. [Results
]
Extensive experimental results demonstrate that the improved BKAoptimized Transformer-BiLSTM prediction model achieves superior performance. It significantly outperforms baseline models
including standard BiLSTM
CNN-BiLSTM
and the unoptimized Transformer-BiLSTM
across critical evaluation metrics such as root mean square error(RMSE)
mean absolute error(MAE)
and mean absolute percentage error(MAPE). Furthermore
by utilizing the improved NSGA-Ⅱ algorithm
the optimization system successfully outputs a set of well-distributed Pareto optimal solutions. These solutions effectively balance environmental protection and economic efficiency
providing power plant operators with a diverse range of flexible control strategies tailored to varying load conditions. [Con
clusion
]
The proposed hybrid optimization strategy proves highly effective in the intelligent management of the single-tower dual-loop WFGD system. By integrating accurate deep learning predictions with robust multi-objective optimization
the strategy successfully mitigates outlet SO
2
fluctuations and substantially reduces desulfurization costs. This research rigorously validates the framework's ability to achieve a balance between environmental protection and economic efficiency
offering a practical technical reference for upgrading industrial emission control systems.