1. 国能南京电力试验研究有限公司
2. 华北电力大学控制与计算机工程学院
3. 国能(浙江北仑)发电有限公司
4. 国能常州第二发电有限公司
纸质出版:2026
移动端阅览
范常浩, 王春, 张文杰, 等. 热电联产机组不同工况下供热附加能耗分布特性研究[J]. 热力发电, 2026,(9).
范常浩, 王春, 张文杰, et al. 热电联产机组不同工况下供热附加能耗分布特性研究[J]. Thermal Power Generation, 2026, (9).
范常浩, 王春, 张文杰, 等. 热电联产机组不同工况下供热附加能耗分布特性研究[J]. 热力发电, 2026,(9). DOI: 10.19666/j.rlfd.202510053.
范常浩, 王春, 张文杰, et al. 热电联产机组不同工况下供热附加能耗分布特性研究[J]. Thermal Power Generation, 2026, (9). DOI: 10.19666/j.rlfd.202510053.
【目的】热电联产是降低燃煤发电机组能耗的有效手段,其供热能耗的精细评估对提升热电联产机组能量利用效率具有重要意义。热电联产机组的热网设备耗电、供热抽汽节流调节和供热抽汽引起主机背压变化等因素均会影响热电联产机组的能量利用,进而产生供热附加能耗。【方法】为了明晰不同工况下热电联产机组供热附加能耗的分布规律,本文以330 MW热电联产机组为案例,建立了热电联产机组变工况计算模型,采用理论对照机组确定供热附加能耗的方法,量化了不同电热负荷条件下附加能耗,进而对比研究了关键运行因素对供热附加能耗的影响规律。【结果】结果表明,热电联产机组热网循环水泵采用汽动泵相较于电动泵,可使机组供热能耗降低0.37~1.74 kg/GJ;供热蝶阀的节流效应会产生4.04~8.57 kg/GJ的附加能耗;供热抽汽会导致低压缸凝汽流减少,进而降低低压缸背压,会产生0.42~1.17 kg/GJ的“负”附加能耗。【结论】研究结果对降低热电联产机组的供热能耗具有指导意义。
[Objective] Combined heat and power(CHP) technology serves as a pivotal and efficient technical approach to reducing the comprehensive energy consumption of traditional coal-fired generating units in thermal power plants
and the refined and accurate quantitative evaluation of heating energy consumption is extremely crucial for further improving the overall energy utilization efficiency and energy-saving operation level of largescale CHP units. In complex actual operational scenarios of cogeneration units
multiple practical influential factors will inevitably interfere with the internal energy conversion and utilization process of CHP units
resulting in variable additional heating energy consumption that significantly deviates from the ideal design operating state. Typical key influencing factors include the auxiliary power consumption of supporting thermal network equipment
the throttling regulation energy loss caused by variable heating extraction steam
and the dynamic variation of main turbine unit back pressure induced by large-fluctuation extraction steam for industrial and civil heating. [Methods] To systematically clarify the spatial and temporal distribution characteristics and quantitative variation rules of the additional heating energy consumption of CHP units under diverse complex off-design operating conditions
this paper takes a widely applied 330 MW commercial CHP unit as the core research subject and establishes a complete and accurate variable-condition thermodynamic calculation model for the full operating range of the unit. With the mature theoretical benchmark unit comparison method adopted to scientifically and quantitatively determine the additional heating energy consumption
this study precisely quantifies the variable additional energy consumption under various coupled working conditions of different electric generation loads and heating supply loads
and further conducts comprehensive comparative analysis to explore the influence laws of key operational parameters on the heating-related additional energy consumption of the unit. [Results] The research results indicate that the application of steam-driven circulating pumps for thermal networks can reduce the heating energy consumption of CHP units by 0.37~1.74 kg/GJ compared with conventional electric-driven pumps. The throttling effect of the heating butterfly valve brings about obvious positive additional energy consumption ranging from 4.04~8.57 kg/GJ. Moreover
heating steam extraction effectively reduces the condensing flow of the low-pressure cylinder and lowers its exhaust back pressure
thereby generating a beneficial negative additional energy consumption of 0.42~1.17 kg/GJ. [Conclusion] The findings of this study clarify the internal generation mechanism of heating energy consumption variation under variable working conditions
and provide reliable theoretical support and practical engineering guidance for energy-saving optimization
load optimal dispatch and low-energy stable operation of large-scale CHP units.
0
浏览量
8
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构