梁凯, 祝令凯, 岳涵, 等. 核电机组联合海水淡化调峰性能与经济性[J]. 热力发电, 2026,(5).
梁凯, 祝令凯, 岳涵, et al. 核电机组联合海水淡化调峰性能与经济性[J]. Thermal Power Generation, 2026, (5).
梁凯, 祝令凯, 岳涵, 等. 核电机组联合海水淡化调峰性能与经济性[J]. 热力发电, 2026,(5). DOI: 10.19666/j.rlfd.202510022.
梁凯, 祝令凯, 岳涵, et al. 核电机组联合海水淡化调峰性能与经济性[J]. Thermal Power Generation, 2026, (5). DOI: 10.19666/j.rlfd.202510022.
核电机组联合海水淡化运行可增强核电站运行灵活性,其调峰性能及经济性有待深入研究。为此,以AP1000核电机组联合多效蒸馏海水淡化系统为研究对象,建立系统热力学-经济性耦合仿真模型,分析系统调峰性能及其经济性,并提出季节差异化运行策略。结果表明,核电机组联合海水淡化后的调峰深度最大为878.5 MW。相比独立运行核电机组,非供暖季采用“优先出力再调海水淡化”策略,工况切换次数从4次增至6次,形成“电价主导-双能适配”模式,系统净收益从359.8万元提升至786.4万元;供暖季采用“优先供暖再调海水淡化”策略,工况切换维持8次不变,形成“电-热-水”协同生产模式,系统净收益从304.5万元升至683.5万元且收益结构均衡。表明该运行策略可同时提升核电站调峰能力与经济效益。
The operation of nuclear power combined with seawater desalination can enhance the operational flexibility of nuclear power plants
but its peak shaving performance and economy still need in-depth research. Therefore
taking the AP1000 nuclear power unit combined with the multi-effect distillation seawater desalination system as the research object
a thermodynamic-economic coupling simulation model of the system was established to analyze the peak shaving performance and economy of the system
and a seasonal differentiated operation strategy was proposed. The results show that the maximum peak shaving depth of the nuclear power unit after combined seawater desalination is 878.5 MW. Compared with independently operating nuclear power units
during the nonheating season
the strategy of “prioritizing output and then adjusting seawater desalination” was adopted. The number of operating condition switches increased from 4 to 6 times
forming a “electricity price dominance-dualenergy matching” model. The net income increased from 3.598 million yuan to 7.869 million yuan. During the heating season
the strategy of “prioritizing heating and then adjusting seawater desalination” was adopted. The working condition switching remained unchanged for 8 times
forming a coordinated production mode of “electricity-heat-water”. The net income increased from 3.045 million yuan to 6.835 million yuan
and the income structure was balanced. The operation of nuclear power plants combined with seawater desalination and the implementation of differentiated peak shaving strategies by season can simultaneously enhance the peak shaving capacity and economic benefits of nuclear power plants.