河海大学电气与动力工程学院
纸质出版:2026
移动端阅览
[1]刘亚乐,马宏忠,陈昱同,等.基于故障树与模糊贝叶斯网络的电抗器故障风险评估[J].热力发电,2026,55(04):175-182.
[1]刘亚乐,马宏忠,陈昱同,等.基于故障树与模糊贝叶斯网络的电抗器故障风险评估[J].热力发电,2026,55(04):175-182. DOI: 10.19666/j.rlfd.202509058.
DOI:10.19666/j.rlfd.202509058.
针对电抗器故障风险评估中过度依赖主观经验的问题,提出一种基于故障树与模糊贝叶斯网络的综合评估方法。通过建立涵盖振动异常、温升异常和油色谱异常3类故障表现的故障树模型,梳理22项风险因子的因果逻辑,并将其转换为贝叶斯网络。采用梯形模糊数处理专家评价的语言不确定性,结合专家权重计算底事件概率,通过正向推理得到电抗器整体故障概率,利用逆向推理和故障重要度指标识别关键故障原因。实例分析表明,该方法能够精准评估故障风险,识别故障原因,并为运维决策提供依据。所提出的基于故障树与模糊贝叶斯网络的综合评估方法有效解决了电抗器故障风险评估中依赖主观经验的问题,具有较高的应用价值和广阔的应用前景。
In view of the limitations of excessive reliance on subjective experience in reactor fault risk assessment
a comprehensive evaluation method based on fault tree and fuzzy Bayesian network is proposed. A fault tree model covering three fault manifestations
abnormal vibration
abnormal temperature rise
and abnormal oil chromatography
is built to clarify the causal logic of 22 risk factors and then mapped into a Bayesian network. Trapezoidal fuzzy numbers are used to handle linguistic uncertainty in expert judgment
and expert weights are combined to obtain basic event probabilities. Forward reasoning yields the overall reactor fault probability
while backward reasoning and fault importance indices are simultaneously involved to identify key fault causes. Case analysis shows that the method accurately assesses fault risk
identifies fault causes
and provides a basis for operation and maintenance decisions. The proposed comprehensive evaluation method based on fault tree and fuzzy Bayesian network effectively reduces subjective dependence in reactor fault risk assessment
offering high practical value and broad application prospects.
高树国,孟令明,张玉焜,等.高压并联电抗器振动疲劳分析与缺陷诊断研究[J].高压电器, 2025, 61(1):215-222.GAO Shuguo, MENG Lingming, ZHANG Yukun, et al.Research on vibration fatigue analysis and defect diagnosis of high voltage shunt reactor[J]. High Voltage Apparatus, 2025, 61(1):215-222.
郭佳熠,沙叶楠,刘云鹏,等.油浸式并联电抗器铁芯振动下的悬浮放电特性[J].高电压技术, 2025, 51(5):2485-2493.GUO Jiayi, SHA Yenan, LIU Yunpeng, et al. Suspension discharge characteristics of oil-immersed shunt reactor under vibration[J]. High Voltage Engineering, 2025,51(5):2485-2493.
马宏忠,侯鹏飞,严岩,等.高压电抗器绕组和铁芯机械故障的混沌特性分析与特征识别[J].电力自动化设备, 2022, 42(5):204-211.MA Hongzhong, HOU Pengfei, YAN Yan, et al. Chaotic characteristic analysis and feature recognition of mechanical failure of high voltage reactor winding and iron core[J]. Electric Power Automation Equipment,2022, 42(5):204-211.
范乃心,李岩,曲德浩.某500 kV变电站66 kV干式电抗器故障分析[J].东北电力技术, 2024, 45(11):50-57.FAN Naixin, LI Yan, QU Dehao. Analysis of 66 kV drytype reactor fault in 500 kV substation[J]. Northeast Electric Power Technology, 2024, 45(11):50-57.
王南,李东,周志强,等.一起500 kV高压电抗器内部过热故障案例分析[J].变压器, 2022, 59(2):72-75.WANG Nan, LI Dong, ZHOU Zhiqiang, et al. Case analysis of a 500 k V HV reactor internal overheating fault[J]. Transformer, 2022, 59(2):72-75.
葛计彬,张波,郝文光,等.基于高频损耗比的干式空心电抗器制造缺陷检测方法及应用探讨[J].变压器,2021, 58(11):61-64.GE Jibin, ZHANG Bo, HAO Wenguang, et al. Discussion on method and application of defect detection for dry air reactor based on high frequency loss ratio[J]. Transformer,2021, 58(11):61-64.
苏基潭.干式空心电抗器故障分析及预防措施[J].冶金动力, 2024(2):1-4.SU Jitan. Failure analysis and preventive measures of drytype air-core reactor[J]. Metallurgical Power, 2024(2):1-4.
赵文清,王强,牛东晓.基于贝叶斯网络的电抗器健康诊断[J].电力自动化设备, 2013, 33(1):40-43.ZHAO Wenqing, WANG Qiang, NIU Dongxiao. Reactor health diagnosis based on Bayesian network[J]. Electric Power Automation Equipment, 2013, 33(1):40-43.
于鑫,李川,李英娜,等.基于模糊层次分析法的干式空心电抗器运行状态评估[J].电力系统及其自动化学报, 2021, 33(1):1-7.YU Xin, LI Chuan, LI Yingna, et al. Evaluation on operation state of dry-type air-core reactor based on fuzzy analytic hierarchy process[J]. Proceedings of the CSUEPSA, 2021, 33(1):1-7.
卫星,李红,王程,等.变电站一次设备健康状态评估及风险预测方案研究[J].电工技术, 2023(8):181-184.WEI Xing, LI Hong, WANG Cheng, et al. Research on health status assessment and risk prediction of primary equipment in substation[J]. Electric Engineering, 2023(8):181-184.
邵宇鹰,房丹,孙宁,等.基于小波变换图像增强与残差神经网络的电抗器状态辨识方法[J].电气开关,2025, 63(1):47-50.SHAO Yuying, FANG Dan, SUN Ning, et al. The state identification method for reactor based on image enhancement with wavelet transform and residual neural network[J]. Electric Switchgear, 2025, 63(1):47-50.
高树国,张明文,吴书煜,等.基于振动感知的油浸式电抗器松动故障检测方法[J].振动与冲击, 2022,41(11):42-49.GAO Shuguo, ZHANG Mingwen, WU Shuyu, et al.Loose fault detection method of oil immersed reactor based on vibration perception[J]. Journal of Vibration and Shock, 2022, 41(11):42-49.
李子彬,王理丽,王子乐,等.基于多元感知信息融合的电抗器故障声纹诊断研究[J].环境技术, 2024,42(2):121-126.LI Zibin, WANG Lili, WANG Zile, et al. Research on voiceprint diagnosis of reactor faults based on multivariate perception information fusion[J]. Environmental Technology, 2024, 42(2):121-126.
赵若妤,马宏忠,魏旭,等.基于EWT及多尺度形态谱的高压并联电抗器故障诊断研究[J].电力系统保护与控制, 2020, 48(17):68-75.ZHAO Ruoyu, MA Hongzhong, WEI Xu, et al. Research on fault diagnosis of a high voltage shunt reactor based on EWT and multiscale spectral spectrum[J]. Power System Protection and Control, 2020, 48(17):68-75.
KABIR S. An overview of fault tree analysis and its application in model based dependability analysis[J].Expert Systems With Applications, 2017, 77:114-135.
MASEGOSA A R, GOMEZ-OLMEDO M. Toward variational structural learning of Bayesian networks[J].IEEE Access, 2025, 13:26130-26141.
ZADEH L. Fuzzy sets[J]. Information and Control, 1965,8:338-353.
PEDRYCZ W, FERNANDO G. Fuzzy systems engineering:toward human-centric computing[M]. Hoboken:John Wiley&Sons, 2007:120-135.
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621