Typical faults and countermeasures of flue gas cooler for coal-fired boilers[J]. Thermal power generation, 2025, 54(7): 111-117. DOI: 10.19666/j.rlfd.202411238.
the pace of low-carbon transformation of power system has been further accelerated. The flue gas waste heat utilization systems have been widely applied in thermal power units. As the core equipment of the flue gas waste heat utilization system
the flue gas cooler has a high failure rate in actual operation due to factors such as limited space in the flue gas layout
high flue dust concentration
and ammonium bisulfate deposition. This not only reduces the recovery of flue gas waste heat
but also increases system resistance
resulting in an increase in fan power consumption and even affecting the unit's load capacity and environmental emission. On the basis of extensive researches on the operation of more than 250 sets of flue gas coolers in the thermal power industry
typical faults commonly found in flue gas coolers
such as leakage
boiler ash deposition
bottom flue ash deposition
and low-temperature flue gas corrosion
are summarized. The causes of the above typical faults and their coupling relationships are analyzed in depth. Moreover
the targeted preventive measures are proposed to provide guidance for transformation and operation/maintenance of flue gas coolers.