LI Hongyou, CHENG Xiaole, XING Yu, et al. Optimization of CMT cladding process path for boiler water-cooled wall tubes[J]. Thermal power generation, 2024, 53(12): 120-128.
LI Hongyou, CHENG Xiaole, XING Yu, et al. Optimization of CMT cladding process path for boiler water-cooled wall tubes[J]. Thermal power generation, 2024, 53(12): 120-128. DOI: 10.19666/j.rlfd.202405092.
面向锅炉水冷壁管的冷金属过渡熔覆工艺路径优化研究
摘要
为对电厂锅炉受热面管进行有效的修复及防腐处理,保障设备的安全运行,针对水冷壁管采用了一种冷金属过渡(cold metal transfer
In order to provide effective repair and rust prevention treatment for hot surface pipe of utility boilers
and to ensure safe operation of the equipment
cold metal transfer(CMT) cladding process is adopted for water-cooled wall tubes. Four cladding process paths are designed
and the reliability of the numerical simulation data is verified through ANSYS numerical simulation and the CMT cladding experimental platform. Comparison based on the process developed in the simulation process shows that
design of the CMT heat source function has a higher degree of agreement in characterizing the temperature field than the conventional arc heat source. Along the material thickness direction
the change rule of the temperature gradient is consistent with the actual morphology of the specimen cross-section. In the case of the same heat input
the average temperature of the cross-melting path is 30 ℃ lower than that of the sequential melting path
the thermal effect of the cross-melting path on the substrate is smaller
and the stress is 22.0 MPa lower. Pipe deformation reduces by 0.18 mm in the cross-over reverse welding path compared with that in the sequential reverse welding path. Comprehensively considering the effects of the residual stresses and the deformations
the cross-reversed melting path is the optimal process route for CMT.