HAN Jinke, WU Jianqun, XIA Yongjun, et al. Comparative study on online monitoring methods for carbon dioxide emissions of 700 MW coal-fired power plants[J]. Thermal power generation, 2025, 54(1): 153-161.
HAN Jinke, WU Jianqun, XIA Yongjun, et al. Comparative study on online monitoring methods for carbon dioxide emissions of 700 MW coal-fired power plants[J]. Thermal power generation, 2025, 54(1): 153-161. DOI: 10.19666/j.rlfd.202404089.
The online monitoring methods for carbon emissions of domestic coal-fired power units in the short and medium term are still mainly based on accounting methods
and the online monitoring methods for carbon emissions are not yet fully developed. An online carbon emission accounting method for large coal-fired power plants is explored based on routine monitoring data from the units' fuel management system
leading to the formation of a rapid carbon emission accounting method. Additionally
five direct online monitoring approaches for carbon emissions are designed to measure volume fraction
flow velocity and humidity of CO_2. Building upon the rapid accounting method
the calculation deviations of different carbon emission calculation methods within different calculation periods are compared. The results show that
as the time span of the calculation period increases
the calculation deviations for carbon emissions tend to stabilize. Results from a 60-day monitoring period indicate that the computational deviations for the system method
monitoring method
modified monitoring method
oxygen balance method
modified oxygen balance method
and calorific value method are –11.5%
7.7%
4.6%
9.7%
7.1%
and 17.0%
respectively. After long-term comparative corrections
all these methods are viable for online monitoring of carbon emissions from coal-fired power plants
providing support for managing and controlling carbon emissions and carbon asset management within these facilities.