CHEN Siyuan, HUANG Chang, WANG Weiliang, et al. Research on creep/fatigue life of high pressure rotor in steam turbine for new power systems[J]. Thermal power generation, 2024, 53(10): 106-113.
CHEN Siyuan, HUANG Chang, WANG Weiliang, et al. Research on creep/fatigue life of high pressure rotor in steam turbine for new power systems[J]. Thermal power generation, 2024, 53(10): 106-113. DOI: 10.19666/j.rlfd.202403060.
Under deep peak shaving and variable operating conditions of thermal power units
significant changes in steam temperature have caused a significant increase in thermal stress in some structures of the units
which accelerated structural damage
and resulted in frequent safety accidents. To solve these problems
by taking the regulating stage rotor of a 300 MW steam turbine as the object
and Ansys software is used to analyze the thermal stress
aerodynamic force
and centrifugal force of the blades. Firstly
structural optimization is carried out on root of the blade to significantly eliminate the unreasonable local stress concentration phenomenon commonly found in conventional calculations. Then
the distribution laws of temperature and stress fields in the regulating stage under different conditions such as steady-state and transient during the deep peak shaving process of thermal power units are revealed. Moreover
the effects of the temperature and stress fields on safety performance of the unit are also investigated. The results indicate that
the maximum equivalent stress increases by about 24% under steady-state conditions with temperature difference of different nozzle groups of 50 ℃. The transient load increase rate of 5% THA/min is about three times higher than that of 2% THA/min
causing low cycle fatigue damage to the rotor. Compared with steady-state operating conditions
increasing the load once a day at a rate of 2% THA/min from half load to full load increases the overall damage by about 38%.