MA Xiuyuan, WEI Fei, XUAN Tianxing, et al. Numerical simulation of flue gas flow measurement technology based on complex flow field[J]. Thermal power generation, 2024, 53(4): 102-111.
MA Xiuyuan, WEI Fei, XUAN Tianxing, et al. Numerical simulation of flue gas flow measurement technology based on complex flow field[J]. Thermal power generation, 2024, 53(4): 102-111. DOI: 10.19666/j.rlfd.202312180.
Flue gas flow is one of the key factors affecting the accuracy of carbon monitoring
and the complex flow field environment with uneven velocity distribution and changing with unit load is the main factor impeding the accurate measurement of flue gas flow. By taking a chimney inlet flue of a 660 MW unit in a power plant as the research object
the influence of the number of points and the layout of the process on measurement accuracy of the flowmeter with four different measurement principles was compared and analyzed based on numerical simulation results of the flue gas flow field. The results show that
the multipoint Pitot tube flowmeter has better adaptability to the complex flow field environment compared with the matrix flowmeter. When the number of measuring points is 28
the deviation of the matrix flowmeter is 1.54 times that of the multipoint Pitot tube flowmeter. The measurement accuracy of the light scintillation flowmeter is greatly affected by the elevation of the installation position
with the maximum deviation being 23.3 times the minimum deviation. This indicates that the light scintillation flowmeter has poor adaptability to complex flow field environments. The ultrasonic flowmeter can be installed obliquely and in multiple channels
with a more flexible and varied process layout
significantly improving its adaptability to complex flow fields. The dual-channel arrangement can control the deviation within ± 1.5%. The research results provide important theoretical basis and data support for the selection of flow meter equipment and process design
and have important theoretical research and engineering application value.