LI Bohang, LU Zhimin, LIAO Yongjin, et al. New optimization method for ammonia/NOx dual control[J]. Thermal power generation, 2023, 52(11): 150-158. DOI: 10.19666/j.rlfd.202301005.
To solve the problems of uneven distribution of NO_x concentration at the outlet and excessive ammonia escape in the actual SCR operation of power plants
the SCR DeNO_x reactor was simulated numerically and a new ammonia injection optimization method for dual control of ammonia slip and nitrogen oxides emission was proposed. Taking the SCR DeNO_x system of a 660 MW unit as an example
a numerical model of visual flow field and DeNO_x reaction was established
and the change of the partitioned outlet NO_x concentration
ammonia slip and partitioned DeNO_x efficiency under different total ammonia nitrogen ratios were analyzed and compared. The results show that the relationship between partitioned DeNO_x efficiency
outlet NO_x and ammonia concentration
with the partitioned ammonia-nitrogen ratio is a two-parts linear relation separated by an inflection point
and the inflection point occurs when partitioned ammonia-nitrogen ratio is about 1.15. On this basis
the present study proposes a new optimization method for ammonia/nitrogen dual control optimization based on the combination of piecewise fitting function and optimization matrix equation. It is predicted that the 660 MW unit by using 5 zones and 42 nozzles for ammonia injection regulation
and the optimized total ammonia injection volume will decrease by 7.2% at the best compared with the uniform ammonia injection working condition. Relative standard deviation of outlet NO_x concentration and ammonia slip volume will decrease to 9.4% and 4.2% respectively
and the outlet uniformity will be significantly improved