HAN Zhonghe, BAI Yaping, CHEN Dongxu, et al. Thermal performance analysis of supercritical carbon dioxide coal-fired power generation system[J]. Thermal power generation, 2023, 52(6): 81-92.
HAN Zhonghe, BAI Yaping, CHEN Dongxu, et al. Thermal performance analysis of supercritical carbon dioxide coal-fired power generation system[J]. Thermal power generation, 2023, 52(6): 81-92. DOI: 10.19666/j.rlfd.202212297.
Based on the first and second laws of thermodynamics
parameters of the supercritical carbon dioxide(S-CO_2) recompression cycle
recompression reheat cycle
partial cooling cycle
partial cooling reheat cycle coalfired power generation system were calculated and analyzed by using MATLAB software. Then
the impact of shunt coefficient
outlet and inlet pressure of the main compressor on the system circulation efficiency
equipment and exergy efficiency of the system were discussed respectively
and the four types of circulation systems were compared and analyzed. The results show that the cycle efficiency varies with the same parameters under different cycle layout or the same cycle layout and different operating parameters. There is a shunt coefficient for exergy efficiency and exergy efficiency to reach an optimal value. There is a coupling relationship between the influence of outlet and inlet pressure of the main compressor and the shunt coefficient on the circulation efficiency. For different parameter changes
exergy efficiency of system is mainly affected by exergy efficiency of different equipment. Reheat can increase circulation efficiency and exergy efficiency of the system
while some cooling cycles are relatively less sensitive to parameter changes.