WANG Gang, BAI Long, JIANG Tieliu. Effect analysis of heat transfer fluid parameters on charging and mechanical performance of TES tank using PCM capsules[J]. Thermal power generation, 2023, 52(5): 62-71.
WANG Gang, BAI Long, JIANG Tieliu. Effect analysis of heat transfer fluid parameters on charging and mechanical performance of TES tank using PCM capsules[J]. Thermal power generation, 2023, 52(5): 62-71. DOI: 10.19666/j.rlfd.202210236.
The effects of different heat transfer fluid(HTF) parameters on charging and mechanical performance of the thermal energy storage(TES) tank using phase change material(PCM) capsules are studied by employing the fluid-solid coupling calculation. The results show that
with the inlet HTF flow velocity increased from 0.000 7 m/s to 0.000 9 m/s
the total heat storage quantity is basically unchanged
the average charging power increases from 5.33 MW to 6.79 MW
and the peak maximum mechanical stress(MMS) of the tank wall decreases. When the initial cold HTF temperature decreases from 610 K to 530 K
the total heat storage quantity increases
the average charging power increases from 5.29 MW to 6.81 MW
but the peak MMS of the tank wall also increases. With the initial hot HTF temperature increases from 730 K to 810 K
the total heat storage quantity increases obviously
the average charging power increases from 3.81 MW to 7.97 MW
but the peak MMS also increases to 159.6 MPa. Hence
to improve the charging performance of the TES tank
on the premise of ensuring the structural safety of steel wall of the TES tank
the inlet HTF flow velocity and initial hot HTF temperature should be increased properly
and the initial cold HTF temperature should be reduced properly.