Analysis of the effect of zero-output modification of low-pressure turbine on the flexibility enhancement of coal-fired power plants equipped with carbon capture
LIU Jun, YUAN Xin, CHEN Heng, et al. Analysis of the effect of zero-output modification of low-pressure turbine on the flexibility enhancement of coal-fired power plants equipped with carbon capture[J]. Thermal power generation, 2023, 52(4): 34-42.
LIU Jun, YUAN Xin, CHEN Heng, et al. Analysis of the effect of zero-output modification of low-pressure turbine on the flexibility enhancement of coal-fired power plants equipped with carbon capture[J]. Thermal power generation, 2023, 52(4): 34-42. DOI: 10.19666/j.rlfd.202209207.
To study the effect of decarbonization on thermal power units
a simulation model is established to analyze the performance changes of the conventional scheme of carbon capture retrofitting in thermal power units.Moreover
a zero-output scheme of a low-pressure turbine is further proposed to improve the flexibility of the units.The conventional method uses the exhaust steam of the intermediate-pressure cylinder as the reboiler heat source
and the zero-output scheme of the low-pressure cylinder cuts off the low-pressure cylinder inlet steam. On one hand
the two methods are analyzed separately by taking a 300 MW coal-fired power unit as an example. On the other hand
the effects of the two schemes on thermal power units of the whole province is predicted by taking a province in northwest China as a research object. The results show that
the unit output range under the conventional scheme is reduced from 87~300 MW to 147~217 MW
and the power supply efficiency under rated operating conditions decreases from 37.32% to 27.02%. The minimum unit load ratio increases to about 70%. The unit load range ise widened to 47~217 MW when the zero output scheme of the low-pressure cylinder is adopted
which is 2.44 times of that of the conventional scheme. For the discussed northwestern province
the thermal power output range is reduced from 1 103~3 940 MW to 1 875~2 793 MW under the conventional scheme
and the output range is widened to 550~2 793 MW under the low-pressure cylinder zero output scheme.