XU Jiamin, LI Wangfan. Research on calculation method of heat transfer coefficient of stepped seal surface[J]. Thermal power generation, 2022, 51(6): 147-153.
XU Jiamin, LI Wangfan. Research on calculation method of heat transfer coefficient of stepped seal surface[J]. Thermal power generation, 2022, 51(6): 147-153. DOI: 10.19666/j.rlfd.202201004.
In order to explore the calculation method of heat transfer coefficient of steam turbine key components
by taking the stepped seal at shaft end of a high-pressure rotor as an example
four commonly used empirical formulas for calculating the heat transfer coefficient of seal surface were analyzed
and the heat transfer coefficient of stepped seals surface with different structural parameters were studied by numerical simulation
and the fitting formula of heat transfer coefficient was obtained. The results show that
the empirical formulas used by Westinghouse
Nanjing Institute of Technology-Harbin Steam Turbine Plant and the Soviet Union are similar in structure
and both are related to parameters like seal gap
height of seal chamber
number of seal teeth
steam thermal conductivity and Reynolds number. The heat transfer coefficient of stepped seal surface is positively correlated with Reynolds number and Prandtl number near the surface. The heat transfer coefficient of the seal teeth surface changes periodically
reaching an extreme value at teeth gap exit
and the heat transfer coefficient of the short tooth exit surface is larger. The heat transfer coefficient decreases with the decrease of seal gap
the increase of seal chamber height and number of seal teeth. The fitting formula of heat transfer coefficient obtained according to the numerical simulation results has good adaptability. The fitting formula can be used to calculate the heat transfer coefficient of stepped seal surface
such as blade top seals
diaphragm seals
shaft end seals
and so on.Moreover
the method provides a way for calculating the heat transfer coefficient of key components of steam turbine with large capacity high-parameter