CHEN Peng, CHANG Jingwei, HUANG Weigang, et al. Adjustment test and optimization strategy study for low reheat steam temperature of tower-type once-through boiler[J]. Thermal power generation, 2022, 51(4): 150-157.
CHEN Peng, CHANG Jingwei, HUANG Weigang, et al. Adjustment test and optimization strategy study for low reheat steam temperature of tower-type once-through boiler[J]. Thermal power generation, 2022, 51(4): 150-157. DOI: 10.19666/j.rlfd.202110219.
Aiming at solving the problem of low reheat steam temperature at medium and low load in a supercritical once-through tower boiler
the low load reheat steam temperature adjustment test was carried out
and the reason for low reheat steam temperature at medium and low load was analyzed. The overall plan for joint treatment of stable combustion burner transformation
heating surface transformation and boiler operation optimization was proposed. After the implementation of the overall plan
the reheat steam temperature of the boiler at medium and low loads significantly increased. The outlet temperature of the reheat steam increased from 537.9 ℃ to 563.9 ℃under 40% BRL condition
and from 537.9 ℃ to 559.4 ℃ under 50% BRL condition
and the coal consumption of power supply of the unit under these two conditions reduced by 1.64 g/(kW·h) and 1.36 g/(kW·h) respectively
and the total annual saving of boiler fuel cost was about 1.25 million yuan. Under 30%BRL condition(the boiler's deep peak load regulation)
the outlet temperature of reheat steam can increase from 541.6 ℃ to 560.9 ℃
with an increase of 19.3 ℃
and the outlet temperature of the superheated steam can increase from 560.8 ℃ to 571.9 ℃