1. 中国电力工程顾问集团中南电力设计院有限公司
2. 浙江大学能源清洁利用国家重点实验室
纸质出版日期:2022
移动端阅览
张春琳, 周志伟, 陈昕, 等. 塔槽耦合光热系统镜场效率研究[J]. 热力发电, 2022,51(5):41-47.
ZHANG Chunlin, ZHOU Zhiwei, CHEN Xin, et al. Study on optical efficiency of tower slot coupling solar thermal power generation system[J]. Thermal power generation, 2022, 51(5): 41-47.
张春琳, 周志伟, 陈昕, 等. 塔槽耦合光热系统镜场效率研究[J]. 热力发电, 2022,51(5):41-47. DOI: 10.19666/j.rlfd.202110190.
ZHANG Chunlin, ZHOU Zhiwei, CHEN Xin, et al. Study on optical efficiency of tower slot coupling solar thermal power generation system[J]. Thermal power generation, 2022, 51(5): 41-47. DOI: 10.19666/j.rlfd.202110190.
太阳能光热发电技术能量输出稳定,可用于电网调峰,是太阳能高效利用的重要方式。其中,塔式光热发电技术的集热储热温度高,系统发电效率高,具有很大的发展潜力。但由于余弦效率的影响,当塔式镜场容量超过一定限值时,镜场效率会随着镜场容量增大而降低,而槽式光热发电技术不受余弦效率影响且几乎与容量无关。因此,提出塔槽耦合的集热方案,并利用MATLAB软件对100 MW塔槽耦合光热发电系统进行光学效率仿真研究。结果表明:在总集热量不变的情况下,塔槽耦合光热系统年均光学效率达到50.65%,比单纯塔式镜场提高3.04百分点;当塔高为260 m时镜场效率比180 m时提高2.52百分点,同时塔与槽的镜场面积比从2.35降低至2.22;针对不同纬度和容量的塔槽耦合系统,提出了塔槽耦合镜场的适用范围,以期为新型太阳能光热发电系统的设计提供参考。
Solar thermal power generation technology is an important way of efficient utilization of solar energy due to its stable energy output and can be used for peak regulation of power grid. Solar tower power generation with high collection and storage temperature has high power generation efficiency and great development potential.However
due to the influence of cosine efficiency
the optical efficiency of the heliostat field will decrease when the capacity exceeds a certain limit. On the contrary
the field efficiency of the trough collector is not affected by cosine efficiency and is independent of capacity. Therefore
a method of coupling tower and trough collector is proposed to improve the efficiency. MATLAB software is used to simulate and study the optical efficiency of the 100 MW tower slot coupling solar thermal power generation system. The results show that
the average annual optical efficiency of the coupling system can reach 50.65% under the condition of constant total heat collection
which is 3.04 percentage points higher than that of single tower system. When the tower height is 260 m
the optical efficiency of the coupling system is 2.52 percentage points higher than that of 180 m
and the ratio of heliostat field area to parabolic trough collector area decreases from 2.35 to 2.22. According to the tower slot coupling system with different latitudes and capacities
the variation regulation of the optical efficiency of the heliostat field is analyzed
and the application range of the tower slot coupling system is proposed
which is expected to provide reference for the design of new solar thermal power generation system.