YU Tao, QIAN Jin, ZHAO Wei, et al. Analysis on temperature and stress of membrane water wall tube in ultra-supercritical circulating fluidized bed boiler[J]. Thermal power generation, 2022, 51(3): 102-108.
YU Tao, QIAN Jin, ZHAO Wei, et al. Analysis on temperature and stress of membrane water wall tube in ultra-supercritical circulating fluidized bed boiler[J]. Thermal power generation, 2022, 51(3): 102-108. DOI: 10.19666/j.rlfd.202107131.
Heat transfer deterioration of supercritical circulating fluidized bed(CFB) boiler in operation causes cracks in water wall
which increases the probability of tube bursting and leakage of water wall. Taking an ultrasupercritical CFB boiler under construction as the research object
a two-dimensional finite element calculation model for membrane water wall is established to analyze the influences of different heat transfer deterioration degrees on the temperature and thermal stress of water wall. The results show that
the changes of the inner and outer wall temperatures of the water wall tubes with azimuth angle θ are consistent between normal heat transfer and heat transfer deterioration. When heat transfer deterioration occurs
the temperature of water wall rises as a whole
and the highest temperature shifts from the middle point of fin to the top of fire side of the water wall tubes.The change trend of deformation of the water wall tube towards fire side is the same as that of temperature. When the heat transfer deteriorates
the temperature and thermal stress of the water wall will exceed the allowable temperature and yield strength of the material
and repeated heat transfer deterioration is an important factor leading to tube bursting of the water wall.