In order to optimize the heat supply scheme for coupled system of wind power and condensing units
the simulation model of a 350 MW extraction condensing unit was established by Ebsilon software
and the functional relationship between the main steam consumption of the condensing unit and the electric/heat load was obtained.Parameters such as the absorbing wind power capacity
main steam consumption and heat load expansion ratio under the original steam extraction heating scheme and other four heating schemes(including adding heat storage tank
adding heat storage electric boiler
adding electric heat pump and heat storage tank coupling devices
and adding absorption heat pump) were calculated. The results show that
compared with the original extraction steam heating scheme
the other four heating schemes can further improve the condensing unit's capacity that be affected by specific limiting factors to absorb wind power. The order of reducing the consumption of main steam from large to small is
adding the coupling device of electric heat pump and heat storage tank
adding the heat storage electric boiler
adding the absorption heat pump
and adding the heat storage tank. The order of the heat load expansion ratio from large to small is
adding the coupling device of electric heat pump and heat storage tank