ZHANG Xiaotao, ZHANG Weidong, MU Haoliang, et al. Pollutant emission of a 600 MW coal-fired boiler coupled with biomass gas reburning[J]. Thermal power generation, 2021, 50(6): 26-32.
ZHANG Xiaotao, ZHANG Weidong, MU Haoliang, et al. Pollutant emission of a 600 MW coal-fired boiler coupled with biomass gas reburning[J]. Thermal power generation, 2021, 50(6): 26-32. DOI: 10.19666/j.rlfd.202010258.
In order to study the influence of different types of biomass and the excess air coefficient in the reburning zone on the combustion process of coal-fired coupled biomass gas
the re-burning processes of a 600 MW tangentially-fired boiler coupled with two 20 t/h gasifiers have been simulated by Fluent software. The effects of straw gas
food waste gas and biogas on the temperature field
composition field and NO_x emissions at the furnace outlet under the conditions with the excess air coefficient of 0.7
0.8 and 0.9 in the re-burning zone were studied. The results show that
biomass gas re-burning can reduce the coal consumption of the boiler and the combustion temperature in the main combustion zone
but the center of the combustion flame in the furnace is moved upward
which increases the temperature of the flue gas at the outlet of the furnace. Biomass gas re-burning can improve the problem of boiler pollutant emissions effectively
the higher the content of hydrocarbon compounds in the biomass gas
the better the effect of reducing nitrogen oxide emissions. The nitrogen reduction effect of straw gas
food waste gas and biogas re-burning increases sequentially
the nitrogen reduction rate of biogas re-burning can reach up to 41.20%.When the excess air coefficient in the re-burning zone is in the range of 0.6~0.8
the biomass gas re-burning system has the best pollutant emission effect. When the excess air coefficient in the re-burning zone continues to increase
the nitrogen reduction effect becomes worse gradually.