ZU Shuai, CHE Yinhui, GUAN Jianjun, et al. Study and prevention of common problems of condenser leakage in nuclear power units[J]. Thermal power generation, 2020, 49(12): 164-169.
ZU Shuai, CHE Yinhui, GUAN Jianjun, et al. Study and prevention of common problems of condenser leakage in nuclear power units[J]. Thermal power generation, 2020, 49(12): 164-169. DOI: 10.19666/j.rlfd.202003065.
核电厂凝汽器泄漏共性问题分析及防治
摘要
核电厂某型凝汽器多次出现因钛管开裂导致海水泄漏问题
严重影响机组安全稳定运行。本文通过对历次事件规律统计分析和钛管金属学分析
确认钛管开裂问题均发生于单列运行或甩负荷工况下
钛管断口性质为疲劳开裂。通过研究该类型凝汽器设计准则
并与行业设计准则对比分析
发现该类型凝汽器在临界流速选取和实际流场不均匀性方面考虑不足
且当机组处于凝汽器单列运行工况下
机组运行功率过高
进一步促使钛管产生流体弹性激振问题。最后
通过加装防振条、预防性堵管以及单列运行机组功率控制等措施
有效降低了凝汽器海水泄漏风险。新设计的该型凝汽器也对此进行了改进
缩短了钛管跨距
从根本上提高了钛管产生流体弹性激振的安全裕度。
Abstract
Seawater leakage of a condenser caused by titanium tubes fracture occurred frequently during the nuclear power units operation
which seriously affects safe and stable operation of the unit. Through statistical analysis of the previous events and metallology analysis of the titanium tube
it is confirmed that the all the cracking of titanium tube occurred under half-side operation of the condenser or the load shedding operating mode of the nuclear power units. Fatigue fracture was found through the micro-images analysis of the cracked titanium tubes. By studying the design criterion of the condenser and comparing with the industry design criterion
the unreasonable calculation of critical and maximum actual velocity was found to be the main root cause. Moreover
the high operating power of the unit under the half-side condenser operation further caused the fluid elastic vibration of the titanium tube. Finally
through the preventive measures such as tubes plugging
adding anti-abrasive strips and unit power control during half-side condenser operation
the seawater leakage risk was reduced effectively. In new design of this kind condenser
the span of titanium tubes was reduced
to improve the safety margin of fluid elastic vibration of the titanium tube fundamentally.