LYU Zhe, ZHANG Jilin, MA Kefei, et al. Correlation between typical water quality parameters and fouling resistance under electromagnetic field[J]. Thermal power generation, 2020, 49(6): 105-110.
LYU Zhe, ZHANG Jilin, MA Kefei, et al. Correlation between typical water quality parameters and fouling resistance under electromagnetic field[J]. Thermal power generation, 2020, 49(6): 105-110. DOI: 10.19666/j.rlfd.202003059.
On the basis of the electromagnetic anti-fouling dynamic simulation experimental platform
the influence of electromagnetic field on three water quality parameters
such as conductivity
pH value and dissolved oxygen
in the process of fouling formation was analyzed
with magnetic induction intensities of 0 and 200 Gs.Moreover
the correlation characteristics between water quality parameters and fouling resistance were studied by using the mathematical statistics method.The results of correlation analysis and partial correlation analysis indicate that
whether the electromagnetic field was applied
the correlation coefficient between conductivity and thermal resistance was the largest
then was the pH value
and the dissolved oxygen was the least
that is
the conductivity had a significant effect on fouling resistance in the heat exchanger.Compared with the situation with nonelectromagnetic field treatment
the correlation degree between water quality parameters and fouling resistance with electromagnetic field was weaker.The correlation analysis between water quality parameters and fouling resistance provides a powerful theoretical basis for establishing the suitable mathematical model and exploring the mechanism of electromagnetic anti-fouling.