Several obvious problems occurred in a subcritical 300 MW circulating fluidized bed(CFB) boiler
such as over high bed temperature
non-uniformity bed temperature distribution
and severe coking near part of the back wall.To solve these problems
the air distribution uniformity on air distributor of the boiler before and after the transformation of air volume adjustment/air distributor for the primary air branch were experimentally investigated.The results show that
for the rectangular air box with dual air inlets
there was obvious non-uniformity along the width direction of the air distributor.By adjusting the airflow volume on the left and right sides of the air box
the average air speed deviation of the left and right wall sections could be reduced
but the average air speed deviation between the central region and the two side regions couldn't be obviously reduced.After the air distributor throttling optimization
the overall uniformity was significantly improved.The low air speed area in the middle was improved
and the uniformity of the bed temperature was also significantly improved after optimization.