GAO Qin, KONG Hao, YANG Hairui, et al. Feasibility analysis for ultra-high parameter CFB boiler with secondary reheat[J]. Thermal power generation, 2020, 49(6): 32-37.
GAO Qin, KONG Hao, YANG Hairui, et al. Feasibility analysis for ultra-high parameter CFB boiler with secondary reheat[J]. Thermal power generation, 2020, 49(6): 32-37. DOI: 10.19666/j.rlfd.202001034.
By comparing the circulating fluidized bed(CFB) boiler with conventional pulverized coal(PC) boiler in steam parameters
heating surface arrangement and regulation approaches
it finds out that the combustion characteristics of CFB boilers are more suitable for secondary reheat technology using ultra-high parameters.The research results show that
the heat transfer temperature difference in CFB boiler furnace is lower than that in PC boiler furnace
but due to the large quantity of solid materials in CFB boiler furnace
the heat transfer coefficient and heat load of high temperature heating surfaces in the CFB boiler are higher than those in PC boiler.The uniformity of combustion in CFB boiler makes the deviation of steam temperature and wall temperature of high temperature and heating surfaces well controlled.The arrangement of secondary reheater in CFB boiler is more flexible
which can be arranged in the tail double-pass and external heat exchanger.Moreover
various heating surfaces
such as evaporative superheater and reheater
can be arranged in the outer loop of CFB
so the height of furnace can be reduced obviously
thus the cost of CFB boiler can be reduced.The CFB boiler has more flexible adjustment methods.By adjusting the mass concentration of gas-solid particles in furnace during operation
and combining with flue gas recirculation and flow regime reconstruction technology
it can regulate the heat load and steam temperature of the high temperature heating surfaces.