PU Xuesen, QI Xindong, YANG Kai, et al. Application of acoustic pyrometer in W-shape flame boiler[J]. Thermal power generation, 2020, 49(7): 93-97. DOI: 10.19666/j.rlfd.201911166.
In order to improve the economy and safety of boiler operation
the furnace temperature of a 330 MW W-shaped flame boiler was measured by acoustic pyrometer. The accuracy of the acoustic pyrometer was verified by a suction thermocouple. The result shows that
the acoustic pyrometer can accurately reflect the distribution and change of flue gas temperature in the furnace. On this basis
carrying out combustion adjustment can avoid the incomplete combustion and slag in local area of the boiler
thus to enhance the economy and safety of the boiler. After combustion adjustment aided by the acoustic pyrometer
the 300 MW unit boiler's thermal efficiency increased by 1.4%