YANG Li, LIU Yonglin, FANG Wei, et al. Operation optimization of cogeneration unit equipped with heat accumulator[J]. Thermal power generation, 2020, 49(4): 70-76.
YANG Li, LIU Yonglin, FANG Wei, et al. Operation optimization of cogeneration unit equipped with heat accumulator[J]. Thermal power generation, 2020, 49(4): 70-76. DOI: 10.19666/j.rlfd.201909227.
配置储热罐后热电联产机组运行优化
摘要
储热罐作为一种蓄能技术可在一定程度上实现热电联产机组热电解耦
提高热电联产机组深度调峰能力。针对目前热电联产机组配置储热罐后的运行优化问题
本文采用Ebsilon软件搭建热电联产机组运行优化分析模型
对某电厂亚临界2×330 MW热电联产机组配置储热罐后运行方式及优化效果进行分析计算。结果表明
配置储热罐后
在单台机组对外供热负荷250 MW时
调峰容量最小提高了额定容量的15.2%
最大提高了额定容量的24.2%。同时
为提高热电联产机组的运行经济性
建议在热电负荷一定时
采取电负荷平均分配、热负荷不均匀分配的运行方式。在此基础上
当该电厂3、4号机组热电负荷处于供需平衡时
运行优化后机组总体热耗率可降低76.1 kJ/(kW·h);当热电负荷处于供需不平衡时
运行优化后机组总体热耗率可降低12.9 kJ/(kW·h);整个采暖季总节煤量为1 618.2 t
总经济收益为129.5万元。该研究结果可为热电联产机组配置储热罐后的安全经济运行提供指导。
Abstract
As an energy storage technology
thermal storage device can solve the power-heat decoupling problem and enhance the deep load peak regulation capacity of cogeneration units. To solve the problem of insufficient research on operation optimization of cogeneration units equipped with heat accumulator
the Ebsilon software is used in this paper to establish the operation optimization analysis model of cogeneration units
and analyze the operation mode and optimization effect of a subcritical 2 ×330 MW cogeneration units equipped with heat accumulator. The results show that
after the heat accumulator is installed
when the external heating load of a single unit is 250 MW
the peak load capacity is increased by 15.2% at the minimum and 24.2% at the maximum. At the same time
in order to improve the operational economy of the cogeneration unit
it is recommended to adopt an operation mode in which the electric load is evenly distributed and the electric load is unevenly distributed. On this basis
when the thermal power load of the No.3 and No.4 units of the power plant is in balance between supply and demand
the overall heat consumption rate after operation optimization can be reduced by 76.1 kJ/(kW·h)
when the thermal power load is in imbalance between supply and demand
the overall heat consumption rate after operation optimization can be reduced by 12.9 kJ/(kW·h)
and the coal saving amount is 1 618.2 t during the whole heating season
and the total economic income is 1.295 million yuan. The results can provide guidance for safe and economic operation of the cogeneration units equipped with heat accumulator.