MA Xiang, DONG Kangtian, ZHENG Jin, et al. Problems and solution in variable-frequency and speed-regulating operation of centrifugal air fans[J]. Thermal power generation, 2019, 48(11): 79-83.
MA Xiang, DONG Kangtian, ZHENG Jin, et al. Problems and solution in variable-frequency and speed-regulating operation of centrifugal air fans[J]. Thermal power generation, 2019, 48(11): 79-83. DOI: 10.19666/j.rlfd.201905093.
It is a very effective way to adopt centrifugal air fans with frequency conversion to save energy. However
the energy-saving effect is not ideal in most cases
and even affects the load capacity of the unit. To solve this problem
large amounts of experimental data were collected
and the problems and causes of the frequency conversion and speed regulation of the power plant fans were analyzed and summarized. Moreover
the feasible solutions for both newly built and in-service units were put forward. The analysis shows that
the main reasons for the problems of variable frequency speed regulation of centrifugal fans are as follows. First
the performance of the air fans does not match the resistance characteristics of the flue gas system. Second
there is large rotate speed difference between the inverter and the air fan performance. Therefore
several countermeasures were proposed
such as improving the matching degree between the fan and flue gas system(for example
optimizing the type selection
increasing the impeller width)
controlling the system effect influence and improving the actual performance of the fan(for example
controlling the installation accuracy in site and improving the air intake condition of the fan through flue duct optimization). This conclusion can provide references for the manufacturers
installation and operating enterprises of air fans.