LIU Xiangliang, WANG Ning, ZHOU Chen, et al. Comparative study on feedwater treatment using AVT and FPOT technology in a supercritical unit[J]. Thermal power generation, 2019, 48(8): 8-14.
LIU Xiangliang, WANG Ning, ZHOU Chen, et al. Comparative study on feedwater treatment using AVT and FPOT technology in a supercritical unit[J]. Thermal power generation, 2019, 48(8): 8-14. DOI: 10.19666/j.rlfd.201903047.
The disadvantages of all volatilized treatment(AVT) of feedwater of a supercritical unit was summerized
the influence of AVT technology on pressure difference of the boiler and deposition of iron oxide scale in high pressure cylinder of steam turbine was analyzed
and the reasons for severe flow accelerated corrosion(FAC) in high pressure heater was also investigated. Moreover
fully-protected oxygenation treatment(OT) conversion test was carried out for feedwater of the supercritical unit
and working mechanism of the feedwater fully-protected oxygenation treatment(FPOT) technology was introduced. Furthermore
after the stable oxygenation operation of the unit
the oxygenation effects of high pressure heater water
precision of automatic oxygenation control program
operation period of condensate polishing treatment and change of iron content in water vapor system were evaluated. In addition
the advantages of feedwater FPOT technology was summerized and some suggestions for future operation were also put forward
in hope of providing reference for feedwater oxygenation in other power plants.