YAO Hongmeng, YAO Jiantao, SUN Yaping, et al. Lay-up corrosion control technology for secondary circuit thermodynamic equipment of high temperature gas-cooled reactor[J]. Thermal power generation, 2019, 48(12): 8-12.
YAO Hongmeng, YAO Jiantao, SUN Yaping, et al. Lay-up corrosion control technology for secondary circuit thermodynamic equipment of high temperature gas-cooled reactor[J]. Thermal power generation, 2019, 48(12): 8-12. DOI: 10.19666/j.rlfd.201902043.
The selection of shutdown maintenance method determines the control level of corrosion during lay-up of the secondary loop of high temperature gas-cooled reactor(HTGR). In this paper
the effect of relative air humidity on corrosion of typical secondary loop materials under dry maintenance was investigated by hygrothermal test. The effects of pH value and oxygen removal method on the wet maintenance of typical secondary loop materials were investigated by means of immersion test and polarization curve. The results show that
under the condition of dry maintenance
the relative air humidity is less than 40%
which can effectively inhibit the corrosion on the material surface. For wet maintenance
a stable passivation film can be formed on the metal surface by increasing pH value of the solution to 10.5 under the saturated oxygen condition. When the pH value is adjusted to 10.0
the corrosion of metals can be effectively controlled by deep deoxygenation.