Analysis on ammonia escape is one of the test projects for denitrification systems in thermal power plants. After flowing through the SCR flue gas denitration system
the fly ash in the flue gas would adsorb a certain amount of escaped ammonia
causing change in physical properties of the ash surface
thus resulting in corrosion and blockage of the heating surface in the boiler tail
which affects safe and stable operation of the thermal power units. To solve this problem
the authors sampled the fly ash at four sites in front of and behind the SCR flue gas denitration system of a 300 MW coal-fired unit
and detected the ammonia and acid gas absorbed by the fly ash. The results show that
as the temperature of the flue gas decreased along the gas flow direction
the mass fraction of the ammonia in the fly ash increased
and there was a certain low temperature residence time in dust collector
the ammonia absorbed by the fly ash increased obviously. The content of sulfur trioxide adsorbed by the fly ash was relatively large
and its change was closely related to the content of sulfur trioxide in the flue gas. Behind the SCR flue gas denitration system
along the flue gas flowing direction
the content of hydrogen chloride adsorbed by the fly ash gradually decreased. The ash surface had an adsorption effect on the escaped ammonia and acid gas
and the two promoted each other
and the adsorption concentration increased with the decrease of temperature
which caused corrosion and clogging of the heating surfaces.