LYU Kai, SHE Yuanyuan, ZHANG Zhixiang, et al. Operation optimization of low-low temperature economizer combined air heater system[J]. Thermal power generation, 2018, 47(6): 105-110.
LYU Kai, SHE Yuanyuan, ZHANG Zhixiang, et al. Operation optimization of low-low temperature economizer combined air heater system[J]. Thermal power generation, 2018, 47(6): 105-110. DOI: 10.19666/j.rlfd.201708090.
To explore the optimum operation mode for the operation optimization of the low-temperature economizer combined heater system under different loads
operation optimization test is carried out in a 300 MW unit. The results show that ambient air temperature is basically unchanged and the temperature of the boiler exhaust shows a linearly increasing trend with the increased air temperature of the air heater. With the temperature rise of the air heater
the heat exchange proportion of the air heater increases approximately linearly at medium and high loads
and at low load the ratio increases at first and then tends to be gentle. Based on the outage state of the low-low temperature economizer combined heater system
within the experimental range
the reduction of the heat rate of steam turbine is linear with the recuperated heat
the increase of the thermal efficiency of the boiler is positively correlated with the increase of air temperature of the air heater outlet
the decrease of coal consumption of power supply is positively correlated with the increase of air temperature of the air heater outlet and the proportion of the absorbed heat at the air heater side. In actual operation
when the air temperature of the air heater outlet is controlled at 70 ℃
the economy of the overall unit is best. The results of this study provide some technical references for improving the economy of thermal power units.