LUO Xiaoxue, ZHANG Xuelai, ZOU Changzhen, et al. Experimental analysis on heat release performance of pulsating heat pipe phase change heat accumulator[J]. Thermal power generation, 2018, 47(4): 123-130.
LUO Xiaoxue, ZHANG Xuelai, ZOU Changzhen, et al. Experimental analysis on heat release performance of pulsating heat pipe phase change heat accumulator[J]. Thermal power generation, 2018, 47(4): 123-130. DOI: 10.19666/j.rlfd.201707080.
low efficiency and serious environmental pollution
a pulsating heat pipe type phase change storage device was designed and a test bench was set up.The effects of initial cooling water temperature
cooling water flow rate and evacuation filling on the exothermic process of pulsating heat pipe were investigated.The heat recovery rate of pulsating heat pipe heat storage device under different operating conditions was calculated.The results show that
the higher the initial temperature of the cooling water
the longer the heat dissipation time of the device is
and the higher the final temperature of the cooling water in the water tank is.The greater the cooling water flow
the shorter the heat release time
but when the cooling water flow increases to a certain value
the total heat release time almost has no change.Whether the pulsating heat pipe is vacuumed has little effect on the exothermic performance of the device.The heat recovery rate of the device decreases with the increase of the initial temperature of the cooling water and only slightly increases with the the cooling water flow rate.