DING Xiao-pingMa'anshan Power Plant. CAUSE ANALYSIS OF ABNORMAL OUTLET-WATER TEMPERATURE FROM LOW-PRESSURE HEATER OF STEAM TURBINE NO.11 IN MA'ANSHAN POWER PLANT[J]. Thermal power generation, 2009, 38(1): 62-63.
DING Xiao-pingMa'anshan Power Plant. CAUSE ANALYSIS OF ABNORMAL OUTLET-WATER TEMPERATURE FROM LOW-PRESSURE HEATER OF STEAM TURBINE NO.11 IN MA'ANSHAN POWER PLANT[J]. Thermal power generation, 2009, 38(1): 62-63. DOI: 10.19666/j.rlfd.2009.01.017.
The outlet-water temperature from heaters is an important supervisory parameter for judging the operation situation of heaters.Taking the low-pressure heater no.2 of steam turbine unit no.11 in Ma'anshan Power Plant as an example
the causes leading to abnormal outlet-water temperature have been analysed
it is believed that the large amount of leakage from copper tubes in heat exchanger of the low-pressure heater no.4 pushes aside the extraction steam of low-pressure heater no.3
and then pushes aside the extraction steam in sixth section of the low-pressure heater no.2
thereby the outlet-water temperature from the low-pressure heater being decreased.The adopted measures to eliminate the fault and the obtained results have been presented.