浙能嘉兴发电有限责任公司的空压机房噪声高达104 dB(A)
严重超标。根据现场实际情况
采取了整修原有空压机隔声罩、安装空压机排风消声器、在空压机房顶棚满铺吸声吊顶、安装钢结构隔声门、增设低噪声轴流风机等措施
整改后
空压房内平均噪声降为82.2 dB(A)
低于国标要求的85 dB(A)
效果明显。
The noise in air compressor house of Zheneng Jiaxing Power Generation Co Ltd is heightened up to 104 dB(A)
seriously exceeding the set standard.These noises include aerodynamic noise
electromagnetic noise
mechanical noise
and radiation noise etc..Based on actual situation in the field
many measures
such as repairing original blimp of the air compressor
installing noise reducer for exhaust air from the air compressor
fully using noise absorption roof on top of the air compressor house
installing steel-framed sound proof door and plastic coated sound proof windows
additionally installing low noise axial-flow fan
and the exhaust air pipe from dryer of the air compressor being connected into silo etc.
have been taken.After implementation
the average noise in the air compressor house has been decreased to only 8.22 dB(A)
being lower than 85 dB(A) specified in National Standard
having remarkable effectiveness.