HOU Wen-long1, HU Man-yin21.Hebei Provincial Electric Power Research Institute. STUDY ON DISTRIBUTION BEHAVIOR OF GAS FLOW IN THE INWARDING BAG TYPE DUST COLLECTOR[J]. Thermal power generation, 2008, (11): 44-48.
HOU Wen-long1, HU Man-yin21.Hebei Provincial Electric Power Research Institute. STUDY ON DISTRIBUTION BEHAVIOR OF GAS FLOW IN THE INWARDING BAG TYPE DUST COLLECTOR[J]. Thermal power generation, 2008, (11): 44-48. DOI: 10.19666/j.rlfd.2008.11.011.
Directing against the operation state of bag type dust collector in the field
the cause resulting in uneven distribution of gas flow have been analysed
and the measures of retrofitting gas entrance and installing additionally guide plates in the lower body of box being put forward.Through calculation using CFD software
the flow field in the dust collector
the distribution of stream lines
and the tracks of particles
etc.before and after retrofitting have been obtained.After retrofitting
the gas flow distribution
the amount of flue gas treated in each part
and the distribution of particles all are more uniform
decreasing the variation of gas flow velocity
making every part in the dust collector to play good role in dust collection
weakening effectively wornout of the bags
enhancing the efficiency of dust collection and the stability in operation.