FENG Li-ping1, LI Ye-feng1, XIAO Xiu-yuan1, et al. CAUSE ANALYSIS ABOUT ABNORMAL DETERIORATION OF TURBINE OIL USED FOR UNIT NO.7 IN SHENTOU POWER PLANT NO.1[J]. Thermal power generation, 2008, (7): 78-80.
FENG Li-ping1, LI Ye-feng1, XIAO Xiu-yuan1, et al. CAUSE ANALYSIS ABOUT ABNORMAL DETERIORATION OF TURBINE OIL USED FOR UNIT NO.7 IN SHENTOU POWER PLANT NO.1[J]. Thermal power generation, 2008, (7): 78-80. DOI: 10.19666/j.rlfd.2008.07.021.
and open cup ageing test under different temperature for oil samples from turbine oil in operation of unit no.7 in Shentou Power Plant No.1
from new turbine oil for replenishment
and from the regenerated turbine oil
it is discovered that the internal factors of turbine oil deterioration are the T501 antioxidant being fully consumed and organic ester existing in the newly added turbine oil
and the external factors are over-temperature points are existing in oil system of the unit and the cooling effect of oil cooler is not good.For these
recommendations of improvement have been put forward.