ZHU Rong, LU Jian-zhong, SUN HuiTaizhou Power Plant. CAUSE ANALYSIS AND DISPOSAL MEASURES OF EARTH FALT IN STATOR OF GENERATOR NO.8 IN TAIZHOU POWER PLANT[J]. Thermal power generation, 2008, (6): 81-83.
ZHU Rong, LU Jian-zhong, SUN HuiTaizhou Power Plant. CAUSE ANALYSIS AND DISPOSAL MEASURES OF EARTH FALT IN STATOR OF GENERATOR NO.8 IN TAIZHOU POWER PLANT[J]. Thermal power generation, 2008, (6): 81-83. DOI: 10.19666/j.rlfd.2008.06.023.
台州发电厂8号发电机定子接地故障原因分析及处理措施
摘要
对台州发电厂8号发电机因定子接地造成机组故障停运的原因进行了分析
并提出了拆除和更换21号槽上层线棒、修复21号槽下层线棒受损绝缘等故障处理方案。
Abstract
The causes leading to shutdown of one unit due to earth fault in stator of generator no.8 in Taizhou Power Plant have been analysed
and disposal scheme of the said fault
including disassembly and replacement of winding bars in upper layer of slot no.21
and repairing the damaged insulation of winding bars in the lower layer of slot no.21