ZHONG Ping1, XU Xiao-chun2, SHAO Wen-chang11.Suzhou Branch of Xi'an Thermal Power Research Institute Co Ltd. TECHNICAL FEATURES AND THERMAL PERFORMANCE ASSESSMENT TEST OF SUPERCRITICAL 600 MW STEAM TURBINE MANUFACTURED BY BEIZHONG-ALSTOM CORPORATION[J]. Thermal power generation, 2008, (6): 53-56.
ZHONG Ping1, XU Xiao-chun2, SHAO Wen-chang11.Suzhou Branch of Xi'an Thermal Power Research Institute Co Ltd. TECHNICAL FEATURES AND THERMAL PERFORMANCE ASSESSMENT TEST OF SUPERCRITICAL 600 MW STEAM TURBINE MANUFACTURED BY BEIZHONG-ALSTOM CORPORATION[J]. Thermal power generation, 2008, (6): 53-56. DOI: 10.19666/j.rlfd.2008.06.015.
The first supercritical 600 MW steam turbine manufactured by Beizhong-Alstom Corporation had been put into operation in Pingwei Power Generation Co Ltd no.2 in March
2007.The main technical features of unit no.3 in said power generation Co Ltd has been presented
and the test results
such as specific heat consumption
output capacity
and cylinder efficiency
etc.in performance assessment test of the unit being analysed
the specific heat consumption of said unit being 7463.5 kJ/kW·h