GU ShanGuodian Changzhou Power Plant. ON-LINE MONITORING OF TUBE-WALL TEMPERATURE FOR SUPERHEATER AND REHEATER IN FURNACE OF SUPER CRITICAL BOILERS[J]. Thermal power generation, 2008, (4): 47-49.
GU ShanGuodian Changzhou Power Plant. ON-LINE MONITORING OF TUBE-WALL TEMPERATURE FOR SUPERHEATER AND REHEATER IN FURNACE OF SUPER CRITICAL BOILERS[J]. Thermal power generation, 2008, (4): 47-49. DOI: 10.19666/j.rlfd.2008.04.012.
The wall-temperature difference is different in regions of different flue gas temperature
of different tube banks
and under different load of large-capacity supercritical and extra-supercritical boilers
the traditional method of estimating tube-wall temperature in the furnace based on temperature measuring points arranged outside the boiler has already been unable to use
the on-line monitoring system should be adopted to fully monitor the wall-temperature of all the tubes in furnace.The functions of on-line monitoring system for a 600 MW supercritical boiler in Changzhou Power Plant
and the features of superheater and reheater temperature conditions have been presented.In the event of slagging and fouling on the water-wall and platen superheater
the said on-line maintoring system can also accurately monitor tube-wall temperature of the final-stage superheater.