The diagnosis process and disposal method of abnormal vibration on bearing no.2 of unit no.1 in Heze Power Plant has been presented. From abnormal vibration occurred on bearing no.2 in October
2002 to additionally installing balance weight onto the rotor in May
2006
through continuous analysis and disposal during the time of more than three years
and starting with increasing dynamic stiffness of the bearing pedestal
the vibration of bearing no.2 has been controlled to below the alarm value and the vibration trouble of bearing no.2 being basically solved.