670t/h锅炉重油燃烧效率低原因分析及解决办法
摘要
原苏联EП670-13.8-545KT型锅炉点火助燃用油燃烧不完全
锅炉起停耗油量大。对此
在燃烧器中心油配风出口加装稳焰器
使锅炉起动时油燃烧完全稳定
起动用油大量减少。
Abstract
The imperfect combustion of fuel oil used for ignition and combustion supporting of EΠ670-13.8-545 KT type boiler manufactured by former Soviet Union leads to big oil consumption in the process of start-up and shut-down of said boiler.For these
a flame stabilizer has been additionally installed at outlet of oil mixed with air in the centre of burner
making the combustion of fuel oil to be perfect and stable in the process of start-up for the said boiler