JIANG Mao-qing1, GAO Hong-pei2, KUANG Wei1, et al. CAUSE ANALYSIS CONCERNING "TURNING-OVER" OF THE BED-MATERIAL IN 300 MW CFB BOILER AND COUNTERMEASURES IN ITS OPERATION[J]. Thermal power generation, 2007, (6): 127-129.
JIANG Mao-qing1, GAO Hong-pei2, KUANG Wei1, et al. CAUSE ANALYSIS CONCERNING "TURNING-OVER" OF THE BED-MATERIAL IN 300 MW CFB BOILER AND COUNTERMEASURES IN ITS OPERATION[J]. Thermal power generation, 2007, (6): 127-129. DOI: 10.19666/j.rlfd.2007.06.036.
The features of dual support-leg structure for circulating fluidized bed (CFB) boiler in Baima CFB Exemplary Power Plant Co Ltd
as well as the turning-over phenomenon of bed-material in debugging process of said boiler have been presented. The caues leading to turning-over of bed-material being analysed
and effective solving measures being put forward. The experience in operation of said boiler is worth to be used for reference to other similar units in our country.