WANG Fu-tan, LUAN Jun, SHAO Xiu-minHuangtai Poewr Plant. ANALYSIS AND REMEDY OF CONDENSATE-BOOSTING PUMP VIBRATION FOR UNIT NO.8 IN HUANGTAI POWER PLANT[J]. Thermal power generation, 2007, (6): 83-86.
WANG Fu-tan, LUAN Jun, SHAO Xiu-minHuangtai Poewr Plant. ANALYSIS AND REMEDY OF CONDENSATE-BOOSTING PUMP VIBRATION FOR UNIT NO.8 IN HUANGTAI POWER PLANT[J]. Thermal power generation, 2007, (6): 83-86. DOI: 10.19666/j.rlfd.2007.06.022.
黄台电厂8号机组凝结水升压泵振动分析与处理
摘要
介绍了对黄台电厂8号机组乙凝结水升压泵振动的分析和处理过程。振动主要由于基础松动引起
对松动的基础重新浇灌了二次灌浆层后
泵组消振达到标准要求。
Abstract
The process of analysis and remedy for condensate-boosting pump vibration of unit no.8 in Huangtai Power Plant has been presented. The vibration is mainly resulted from looseness of the foundation. After re-grouting secondary grout layer on the loose foundation
the elimination of pump vibration satisfied the requirements of standard.