L Lin-zhi(Laiwu Power Plant. CAUSE ANALYSIS AND COUNTERMEASURES FOR HIGH-PRESSURE HEATER LEAKAGE IN THERMAL POWER PLANT[J]. Thermal power generation, 2007, (5): 46-48.
L Lin-zhi(Laiwu Power Plant. CAUSE ANALYSIS AND COUNTERMEASURES FOR HIGH-PRESSURE HEATER LEAKAGE IN THERMAL POWER PLANT[J]. Thermal power generation, 2007, (5): 46-48. DOI: 10.19666/j.rlfd.2007.05.013.
火电厂高压加热器泄漏原因分析及对策
摘要
分析了高压加热器泄漏原因
认为主要为U形管本身泄漏以及管口与管板胀接、焊接等处存在缺陷所致。针对不同泄漏
提出了相应的处理对策
减少了高压加热器泄漏故障。
Abstract
The causes of high-pressure heater leakage have been analysed
it is believed that the main causes leading to leakage are defects in U-tube bending and in expanding jouts between tube ends and tube plate
as well as defects in welding etc..Directing against different causes of leakage
corresponding countermeasures have been put forward