ZHANG Min1, BAI Qiang1, LIU Yu-ping2(1.Xi'an Thermal Power Research Institute Co Ltd. TEST STUDY ON MIXEDLY BURNING GANGUE IN CFB BOILER[J]. Thermal power generation, 2007, (4): 55-57.
ZHANG Min1, BAI Qiang1, LIU Yu-ping2(1.Xi'an Thermal Power Research Institute Co Ltd. TEST STUDY ON MIXEDLY BURNING GANGUE IN CFB BOILER[J]. Thermal power generation, 2007, (4): 55-57. DOI: 10.19666/j.rlfd.2007.04.014.
The results of test study on mixedly burning gangue in circulating fluidized bed(CFB) boiler have been presented.It has been suggested to define the ratio of mixed gangue by using the ash content of furnace-incoming fuel as received basis
and to calculate the practical amount of mixed gangue
and combining with concrete example
the problems needing to pay attention for reasonably determining the ratio of mixed gangue and for operation of CFB boiler under condition of mixedly burning gangue have been analysed
the results have certain reference value for some power plants adopting CFB boilers to reasonably use gangue for power generation based on their respective actual situation.